HMS Power Supply Monitor Model 9161 HMS

 

 

Communications Receiver:
Agile Frequency Ranges      48 - 120 MHz
Frequency Steps                25 kHz Frequency
Accuracy                          ± 5.0 kHz
Input Level                         0 dBmV ± 20 dB
Interference Rejection        10 dBc @ ± 250 kHz
                                       20 dBc @ ± 600 kHz
Spurious Outputs               -30 dBmV max., 5 to1000 MHz

Communications Transmitter:
Agile Frequency Ranges         5 - 42 MHz
Frequency Steps                   25 kHz
Frequency Accuracy              0.01%, unmodulated mark
Occupied Bandwidth              300 kHz @ -40 dB
RF Output Level                    45 dBmV ± 3 dB
RF Adjustment Range            0-30 dB, 2 dB steps
Spurious Outputs                 -55 dBc max., 5 to 1000 MHz


Monitored Parameters:
Analog Parameters:
Forward RF Measurement   -20 to 20 dBmV; 0.5 dB steps
                                         ± 3 dB accuracy
Return RF Measurement     -20 to 20 dBmV; 0.5 dB steps
                                         ± 3 dB accuracy
Total Battery Voltage          0 to 60 VDC; 0.25 VDC steps
                                         ± 1 VDC accuracy
Individual Battery Voltage   10 to 18 VDC; 0.1 VDC steps
                                        ± 0.25 VDC accuracy
Output AC Voltage             0 to 110 VAC; 0.5 VAC steps
                                        ± 5 VAC accuracy
Output AC Current             0 to 30 amps; 0.5 amp steps
                                        ± 1 amp accuracy
Transponder Temperature  -40 to 100 deg C; 1 deg steps
                                        ± 5 deg accuracy
Battery Temperature          -40 to 80 deg C; 1 deg steps
                                        ± 5 deg accuracy

 

Model 9161 HMS

 

 Other Parameters:
Power Supply Status            Normal/Standby
Enclosure Door Tamper         Normal/Tamper
General Alarm                      Normal/Alarm
60 VAC Alarm                      Normal/Alarm
Line PowerOn/Off & Standby Test
Remote Control


Mechanical Specifications:
Dimensions 8.125” x 4.5” x 1.5” RF ConnectorFemale “F”
Power Supply Interface Alpha compatible
Weight 0.5 pound max.

Power Supply Requirements:
40 to 110 Vac, 50 to 60 Hz, 1.6W nominal

Other Features:
AC Line Failure Monitoring (On/Off Status) Battery
Compartment Temperature Probe

 

 

Print  
 